The next big advance was patch-clamp recording (Neher
and Sakmann 1976). Micropipettes were sealed against
a cell membrane that had been cleaned of connective tissue
by treatment with enzymes. A very-high-resistance seal
resulted [(2–3) × 107 Ω] that allowed one to see the opening
and closing of individual channels. For this work, Erwin Neher and Bert Sakmann received the Nobel Prize in Physiologyor Medicine in 1991.
Fifty years ago, Erwin Neher and Bert Sakmann published a Nature paper on their recording of discrete, step-like currents of a few picoamps passing through individual acetylcholine receptor channels of frog muscle fibers. This observation, the first on native channels, immediately ended the decade-long dispute about the presence of ion channels on cell membranes by convincing even the most reluctant scientists that this was indeed the case. More importantly, however, the ability to record single-channel currents revolutionized the study of ion channels because it enabled scientists to observe their behavior individually in real time. We could observe them change conformation, jumping from the closed state to the open state and back again. This level of detail provided an unprecedented understanding of the gating mechanisms, conductance, and kinetic properties of channels. This retrospective illustrates the scientific context in which all of this occurred as well as its immediate and current impact on the investigation of ion channels.
Below is the graphical abstract
The review is a nice mix of history and science. I recommend it to anyone wanting to learn more about the patch clamping. Here is the section about how Neher and Sakmann met and began their collaboration.
This crucial scientific objective of recording single-channel
currents apparently fraught with insurmountable
problems found a solution when it crossed the paths of two
young German scientists, Erwin Neher and Bert Sakmann.
Erwin Neher had returned to Germany in 1967 after a year
on a Fulbright studentship at the University of Wisconsin,
where he studied spectroscopy of macromolecules, and was
now looking around for some PhD project in biophysics,
possibly related to nerve excitation. This search brought him
to Prof Dieter Lux’s laboratory at the Max-Planck-Institutfür Psychiatrie in Munich to study synaptic mechanisms in
snail motor neurons. To avoid space clamp problems, Lux
recommended that his young postdoc use suction pipettes
to record currents. This suggestion would be recalled a
few years later when trying to record elementary currents
through single-channel.
While at Prof Lux’s laboratory, Neher met Bert Sakmann
who had come to learn the basics of voltage clamping synaptic
currents in snail neurons before moving to University College London to work in Bernard Katz’s biophysics
laboratory on that topic. Sakmann was eager to understand
the fundamental mechanisms of the synapse that Neher
was studying because he believed they were essential to
comprehending the central nervous system’s excitability.
For this reason, they had many lively discussions... It was in that period that Katz, in collaboration with
Ricardo Miledi, suggested that elementary current events
through individual ACh receptor channels caused the noise
observed in the membrane potential recordings when ACh
was applied to the end-plates of frog skeletal muscle (Katz
& Miledi 1972 ).
Neher and Sakmann met again at the Max-Planck-Institutfür Biophysikalische Chemie in Götttingen in 1973.
Neher had joined the Institute to gain expertise in single-channel
recording in artificial lipid bilayers, and Sakmann
had returned from London and was offered by Prof Otto Creutzfeldt to run his independent laboratory. Given their
clear communion of interests, they soon agreed on collaborating
to measure single-channel currents.
I’ll end by quoting Catacuzzeno and Franciolini's concluding paragraph.
The single-channel recording technique, with its many configurations
for different experimental needs, has been invaluable
in many areas of research over the years. The technique
certainly has its limitations, such as low data throughput or
the requirement for highly skilled operators. However, there
is a general consensus that classical single-channel recording
with patch clamp, when performed by expert scientists,
remains the technique capable of providing the highest-quality
data and the most reliable answers to subtle questions
about ion channels. Despite being the oldest single-molecule
technique and having changed little over the last 45 years,
this technique remains a milestone in the study of protein
conformational dynamics. Due to its unparalleled recording
length (with many thousands of openings and closures) and
sub-millisecond time resolution, it is the only technique that
allows one to observe, in real time, when channels open or
close (i.e., switch conformation) while remaining in their
natural environment within the cell membrane.
There are a lot of freshmen (over five hundred), so I talked to two sections of HC 1000, one on Wednesday afternoon and the other on Thursday morning. The enrollment is so large that we had to meet in the Oakland Center Founders Ballroom. It may be the largest group I've ever addressed. As I expected, the students were lively and engaged, and asked many good questions. Below is an approximate transcript of my talk. I had no Powerpoint to go with it, so the transcript gives you everything except some hand-waving.
Introduction
How did you enjoy The Fellowship of Puzzlemakers? I thought it was good. Scientists solve puzzles, too. We’re a lot like the folks in the book. Today I’m gonna give you an example of solving a scientific puzzle. This is a story from my own personal experience. Solving puzzles for a living is great fun.
You know how the book would shift from past to present, back and forth, so it was hard to keep track of when something was happening? I’m gonna do that in this talk. Beware.
NIH
For seven years, from 1988 to 1995, I worked at the National Institutes of Health. NIH is like a big college campus with faculty but no students (what could be nicer?….no, just kidding, we love you students). It’s in Bethesda, Maryland which is just north of Washington, DC. As they say, it’s “inside the beltway.” If you know DC, it’s along the subway system’s red line. It’s so big it has its own stop.
NIH is the greatest biomedical research institution anywhere, ever. At least it used to be. Don’t get me started about what’s happened in the last two years. In any case, during the 1990s it was the best place to do biomedical research.
It’s a little surprising that I was at NIH, because I’m a physicist. I was a graduate student at Vanderbilt University, studying physics, and I especially liked electricity and magnetism. I’m a theoretical physicist, which means I use math and computer simulations to study problems. I can’t solve a puzzle definitively using these tools, but I can make predictions that experimentalists can then test. And, mathematical models can provide much insight into what is happening in a messy experiment. Finally, I also was interested in how physics applies to medicine and biology. Things like how nerves and muscle work. So, I ended up at NIH as a theoretical physicist interested in bioelectricity. One of the projects I was working on was electrical stimulation of the heart. This occurs in pacemakers, where a pulse of current is passed through an electrode to stimulate the heart.
Dekker
Sometimes at NIH I would get tired by the end of the day, and I would stop working on my computer calculations (all that sitting and typing can be exhausting) and would instead go browse in the NIH library. Not the National Library of Medicine, also on the NIH campus, because it has closed stacks. I preferred the more user-friendly NIH library in the basement of the Clinical Center. One day I stumbled upon this paper by an old Dutch doctor by the name of Egbart Dekker. Back in 1970 Dekker had done experiments where he found four different ways to stimulate the heart. He could make his electrode negative (a cathode) and the heart would be excited right after he turned the current on. He called this “cathode make” excitation (make because it happened when the current turned on). He could switch his polarity so the electrode was positive (an anode), and excite by a mechanism he called “anode make.” So both a cathode and anode could excite the heart, but the anode needed a bigger current.
He also saw break excitation. To understand this, I have to tell you a little about action potentials. At rest, the inside of a heart cell is negative (it has a net negative charge). When an action potential fires, sodium channels in the cell membrane open and positively-charged sodium ions rush in through these channels and the inside becomes positive. The inside then remains positive for a while, until potassium channels open, positively charged potassium ions rush out, and the inside returns to rest (negative, where it started). That’s the action potential. If you fire an action potential, and then try to fire a second one soon after, it doesn’t work. The cell is “refractory.” You have to wait a while until the cell returns to rest before you can excite it again.
When the heart was refractory, Dekker applied a long cathodal stimulus. When the stimulus turned on nothing happened because the cells under the electrode were refractory. But when he turned the stimulus off, the heart tissue under the cathode fired an action potential. That’s surprising, because you usually don’t excite the heart by turning a stimulus off. He called that “cathode break” excitation. Break, because it didn’t happen until he turned the stimulus off. He could also do break excitation with an anode: “anode break” excitation.
As I read Dekker’s article, I thought “that’s odd.” Some people think science proceeds through great “Eureka!” moments when a scientist sees the answer in a flash of insight. But more often, science proceeds by someone saying “Hmmmm…. That’s funny. What’s going on?”
Now I had my puzzle: why are there four mechanisms of excitation of the heart? What's happening during each one? Dekker had been my puzzlemaker. He left the puzzle for me to solve. It’s almost as if he had put the puzzle in a bottle, corked it, and thrown it into the sea, and 20 years later I had stumbled upon it when walking on the beach.
Grad School
Now, to explain how I solved this puzzle, I have to go back to when I was in graduate school. I was studying along with my PhD advisor John Wikswo and his research associate Nestor Sepulveda. Nestor was a better programmer than me, and he knew how to use this fancy new technique called finite elements. He had been using this method to do simulations of the voltage created when you use a small electrode in a sheet of heart tissue. The tissue was anisotropic, meaning it had different electrical properties along the grain of the muscle fibers than across them. Just like a pork chop is easier to cut in one direction than the other, the electrical properties are different in the two directions. Nestor found that when you apply a cathodal stimulus, the voltage across the cell membrane right under the electrode is made positive by the stimulus: depolarization. (Remember, at rest the tissue is negative inside, so making it less negative means depolarization). He also predicted two weaker regions of negative voltage across the membrane (hyperpolarization, more negative than rest) on each side of the electrode along the fiber direction. So we were able to see where the tissue was depolarized and hyperpolarized. However, this model did not have ion channels in the membrane that could open and close, so it couldn’t predict action potentials.
At NIH, I decided to use Nestor’s model, but I added ion channels so I could look at action potentials firing and refractory periods. I used the only ion channel model I knew: one for a nerve axon (some of you might have heard of it: the Hodgkin and Huxley model). I wrote the program and started applying stimuli. And guess what? I was able to simulate all four types of excitation: cathode make, anode make, cathode break, and anode break! I was very pleased, so I wrote up a paper and sent it in for publication.
Peer Review
When you submit a paper to a journal, it undergoes peer review. The journal editor sends copies of the paper to several scientists (you don’t know who) to read it, make comments on it, and recommend if it should be accepted, revised, or rejected. My reviews came back: rejection! The reviewers said that the idea was interesting, but the model of ion channels was wrong. I shouldn’t use a nerve model for the heart.
Peer review is important, but it’s not fun. Sometimes when I get back reviewers’ comments, I want to go play racquetball. But when I hit the ball, instead of thinking it’s a ball I pretend its the reviewer’s head. Once I calmed down, however, I said to myself “you know, Brad, why would anyone use a nerve model for the heart?” Those reviewers had a good point. I needed a heart model for the ion channels. So I found one, rewrote the computer program, and redid all the calculations. The results were as before—I got all four types of excitation—but now they looked even more like what Dekker saw.
Experiment
I revised my paper and sent it to a different journal. I also sent a copy to John Wikswo, my former PhD advisor. Wikswo is an experimentalist, and his lab had just the technique to test this model, at least in an animal experiment. You apply a dye to the heart, and it gets absorbed into the cell membrane. When you shine green light on the heart, the dye absorbs the light and then emits red light. The amount of red light you get depends on the voltage across the cell membrane. In this way, you can use optical methods—cameras, lasers, and lenses—to measure voltage. It was exactly what we needed.
So Wikswo and his post doc Marc Lin decided to do the experiment. I waited a few months (these things take a while). Then Wikswo calls me on the phone and says “What would you say if I told you that my experiment looks exactly like your model for cathode make, anode make, and cathode break excitation, but is completely different for anode break?” I panicked, and started to list all the assumptions in my model that might explain this disaster. Wikswo just laughed and said “I didn’t say your model doesn’t match our experiment. I merely asked ‘what would you say if….’”. Ha, Ha. Very funny, Wikswo. The experiments did match the model, and I (really, we) had solved Dekker’s puzzle.
My theoretical paper was eventually published in the IEEE Transactions on Biomedical Engineering (it’s the paper I asked Dr. Harper to send to you all, so you can have a look if you want to see what a scientific paper looks like) and Wikswo’s experimental paper was published in the Biophysical Journal, and we all lived happily ever after.
Mechanisms
Before I end, let me tell you a little more about the mechanism for break excitation. When you apply a cathodal stimulus to refractory tissue, nothing happens. Right under the electrode, the tissue is strongly depolarized. Along the fiber direction, it is hyperpolarized in two places. The hyperpolarization pulls the refractory tissue back toward rest. In other words, it forces the tissue to end its refractory period early. It creates two islands of excitable tissue in a sea of refractory tissue. When the stimulus ends, the depolarization under the electrode can diffuse into these hyperpolarized and excitable regions, exciting them. This launches two action potentials that then eventually excite the whole heart. It was the hyperpolarization forcing the refractory tissue back to rest so it becomes excitable that was the key insight.
This insight turned out to be important in defibrillation. During fibrillation, the heart has many action potentials propagating chaotically, like turbulence. So the heart is quivering instead of beating in synchrony to pump blood. If your heart goes into fibrillation, it doesn’t pump blood you die in a few minutes unless you defibrillate. To do this, you apply a strong shock to the whole heart (like in the hospital TV shows, when they put the paddles on the chest and yell "clear!"). The shock can stop the action potentials, but when the shock ends it can cause break excitation. So, a defibrillation shock may fail if restarts fibrillation because of break excitation. There are some tricks you can do to prevent this from happening, which means you more effectively defibrillate. This idea is important. But applying these mechanisms to defibrillation wasn’t my idea, however, so I won’t talk much more about it.
Conclusion
So that’s my story. Imagine getting to spend you career solving puzzles like this one. I can understand why those folks in the book wanted to form a fellowship of puzzlemakers. That’s what science is. A Fellowship of Puzzlemakers and Puzzlesolvers. It’s a great life.
This year’s theme is “Advancing Global Health Equity: The Ethical Foundation of Medical Physics.” What a refreshing idea. Here in the United States, our government is constantly demonizing all attempts at diversity, equity, and inclusion. I’m glad the International Organization of Medical Physics decided to reassert emphatically that equity is a good thing, and in particular health equity is a noble goal. Marie Curie personifies diversity, equity, and inclusion. She became a scientist at a time when science was not diverse and almost no women were included in the profession.
Equity is the absence of unfair, avoidable or remediable differences among groups of people, whether those groups are defined socially, economically, demographically, or geographically or by other dimensions of inequality (e.g. sex, gender, ethnicity, disability, or sexual orientation). Health is a fundamental human right. Health equity is achieved when everyone can attain their full potential for health and well-being.
In 1896, Henri Becquerel along with Marie and Pierre Curie
discovered radioactivity (they shared the physics Nobel Prize
in 1903), having found “α rays” emitted by uranium ore.
Alpha rays turned out to be α particles and the main emitters
were the nuclei of radium and polonium. Marie Curie
won her second Nobel Prize (this time in chemistry) in 1911
for the discovery of these new elements.
Below is the International Day of Medical Physics 2026 poster, designed by Francesca Vittorini, Camilla Petrucci, and the Health Physics Team from the San Salvatore Hospital in L’Aquila, Italy. It’s not quite as good as my favorite, the 2024 poster by Lavanya Murugan, but it’s close. According to the International Day of Medical Physics website, “The ascending staircase symbolises progress, access, and the shared journey toward more equitable healthcare for all. The diverse patient–professional interactions reflect compassion, inclusivity, and the human-centred role of medical physicists in supporting safe, effective, and ethical medical care worldwide.”
There is a famous quote by Marie Curie
Nothing in life is to be feared, it is only to be understood. Now is the time to understand more, so that we may fear less.
I personally find hope in this quote. Over the last two years I’ve feared that my once-great country is becoming a place I no longer recognize. Curie reminds me that the key is for me to understand what is happening in the United States and who is responsible, so I’ll be better able to recognize and oppose changes I don’t support. Our recent midterm elections give me hope that others recognize and oppose, but do not fear, the current administration too.
Sorry for getting all political, but these days it seems I have little choice. Happy International Day of Medical Physics to you all, and let’s work toward a more diverse, equitable, and inclusive profession and society. And above all, Happy Birthday, Marie Curie!
International Day of Medical Physics coordinators message.
I am an emeritus professor of physics at Oakland University, and coauthor of the textbook Intermediate Physics for Medicine and Biology. The purpose of this blog is specifically to support and promote my textbook, and in general to illustrate applications of physics to medicine and biology.