In the January 9 post of this blog, I challenged readers to find the electrical potential V(z) that will give you the electric field E(z) of Eq. 6.10 in the 5th edition of Intermediate Physics for Medicine and Biology
In other words, the goal is to find V(z) such that E = − dV/dz produces Eq. 6.10. In the comments at the bottom of the post, a genius named Adam Taylor made a suggestion for V(z) (I love it when people leave comments in this blog). When I tried his expression for the potential, it almost worked, but not quite (of course, there is always a chance I have made a mistake, so check it yourself). But I was able to fix it up with a slight modification. I now present to you, dear reader, the potential:
How do you interpret this ugly beast? The key is the last term, z times the inverse tangent. When you take the z derivative of V(z), you must use the product rule on this term. One derivative in the product rule eliminates the leading z and gives you exactly the inverse tangent you need in the expression for the electric field. The other gives z times a derivative of the inverse tangent, which is complicated. The two terms containing the logarithms are needed to cancel the mess that arises from differentiating tan−1.
I don’t know what there is to gain from having this expression for the potential, but somehow it comforts me to know that if there is an analytic equation for E there is also an analytic equation for V.
Friday, June 26, 2015
Friday, June 19, 2015
Dr. Euler’s Fabulous Formula Cures Many Mathematical Ills
Dr. Euler's Fabulous Formula, by Paul Nahin. |
eiθ = cosθ + i sinθ .
I liked the book, in part because Nahin and I seem to have similar tastes: we both favor the illustrations of Norman Rockwell over the paintings of Jackson Pollock, we both like to quote Winston Churchill, and we both love limericks:
I used to think math was no fun,Nahin’s book contains a lot of math, and I admit I didn’t go through it all in detail. A large chunk of the text talks about the Fourier series, which Russ Hobbie and I develop in Chapter 11 of IPMB. Nahin motivates the study of the Fourier series as a tool to solve the wave equation. We discuss the wave equation in Chapter 13 of IPMB, but never make the connection between the Fourier series and this equation, perhaps because biomedical applications don’t rely on such an analysis as heavily as, say, predicting how a plucked string vibrates.
‘Cause I couldn’t see how it was done.
Now Euler’s my hero
For I now see why zero,
Equals eπi + 1.
Nahin delights in showing how interesting mathematical relationships arise from Fourier analysis. I will provide one example, closely related to a calculation in IPMB. In Section 11.5, we show that the Fourier series of the square wave (y(t) = 1 for t from 0 to T/2 and equal to -1 for t from T/2 to T) is
y(t) = Σ bk cos(k2πt/T)
where the sum is over all odd values of k (k = 1, 3, 5, ....) and bk = 4/(π k). Evaluate both expressions for y(t) at t = T/4. You get
π/4 = 1 – 1/3 + 1/5 – 1/7 +…
This lovely result is hidden in IPMB’s Eq. 11.36. Warning: this is not a particularly useful algorithm for calculating π, as it converges slowly; including ten terms in the sum gives π = 3.04, which is still over 3% off.
In Figure 11.17, Russ and I discuss the Gibbs phenomenon: spikes that occur in y(t) at discontinuities when the Fourier series includes only a finite number of terms. Nahin makes the same point with the periodic function y(t) = (π – t)/2 for t from 0 to 2π. He describes the history of the Gibbs phenomena, which arises from a series of published letters between Josiah Gibbs, Albert Michelson, A. E. H. Love, and Henri Poincare. Interestingly, the Gibbs phenomenon was discovered long before Gibbs by the English mathematician Henry Wilbraham.
Fourier series did not originate with Joseph Fourier. Euler, for example, was known to write such trigonometric series. Fourier transforms (the extension of Fourier series to nonperiodic functions), on the other hand, were first presented by Fourier. Nahin discusses many of the same topics that Russ and I cover, including the Dirac delta function, Parseval’s theorem, convolutions, and the autocorrelation.
Nahin concludes with a section about Euler the man and mathematical physicist. I found an interesting connection to biology and medicine: when hired in 1727 by the Imperial Russian Academy of Sciences, it was as a professor of physiology. Euler spent several months before he left for Russia studying physiology, so he would not be totally ignorant of the subject when he arrived in Saint Petersburg!
I will end with a funny story of my own. I was working at Vanderbilt University just as Nashville was enticing a professional football team to move there. One franchise that was looking to move was the Houston Oilers. Once the deal was done, folks in Nashville began debating what to call their new team. They wanted a name that would respect the team’s history, but would also be fitting for its new home. Nashville has always prided itself as the home of many colleges and universities, so a name out of academia seemed appropriate. Some professors in Vanderbilt’s Department of Mathematics came up with what I thought was the perfect choice: call the team the Nashville Eulers. Alas, the name didn’t catch on, but at least I never again was uncertain about how to pronounce Euler.
Friday, June 12, 2015
Circularly Polarized Excitation Pulses, Spin Lock, and T1ρ
In Chapter 18 of the 5th edition of Intermediate Physics for Medicine and Biology, Russ Hobbie and I discuss magnetic resonance imaging. We describe how spins precess in a magnetic field, Bo = Bo k, at their Larmor frequency ω, and show that this behavior is particularly simple when expressed in a rotating frame of reference. We then examine radio-frequency excitation pulses by adding an oscillating magnetic field. Again, the analysis is simpler in the rotating frame. In our book, we apply the oscillating field in the laboratory frame’s x-direction, B1 = B1 cos(ωt) i. The equations of the magnetization are complicated in the rotating frame (Eqs. 18.22-18.24), but become simpler when we average over time (Eq. 18.25). The time-averaged magnetization rotates about the rotating frame’s x' axis with angular frequency γB1/2, where γ is the spin’s gyromagnetic ratio. This motion is crucial for exciting the spins; it rotates them from their equilibrium position parallel to the static magnetic field Bo into a plane perpendicular to Bo.
When I teach medical physics (PHY 326 here at Oakland University), I go over this derivation in class, but the students still need practice. I have them analyze some related examples as homework. For instance, the oscillating magnetic field can be in the y direction, B1 = B1 cos(ωt) j, or can be shifted in time, B1 = B1 sin(ωt) i. Sometimes I even ask them to analyze what happens when the oscillating magnetic field is in the z direction, B1 = B1 cos(ωt) k, parallel to the static field. This orientation is useless for exciting spins, but is useful as practice.
Yet another way to excite spins is using a circularly polarized magnetic field, B1 = B1 cos(ωt) i – B1 sin(ωt) j. The analysis of this case is similar to the one in IPMB, with one twist: you don’t need to average over time! Below is a new homework problem illustrating this.
Now let’s assume that an RF excitation pulse rotates the magnetization so it aligns with the x' rotating axis. Once the pulse ends, what happens? Well, nothing happens unless we account for relaxation. Without relaxation the magnetization precesses around the static field, which means it just sits there stationary in the rotating frame. But we know that relaxation occurs. Consider the mechanism of dephasing, which underlies the T2* relaxation time constant. Slight heterogeneities in Bo mean that different spins precess at different Larmor frequencies, causing the spins to lose phase coherence, decreasing the net magnetization.
Next, consider the case of spin lock. Imagine an RF pulse rotates the magnetization so it is parallel to the x' rotating axis. Then, when the excitation pulse is over, immediately apply a circularly polarized RF pulse at the Larmor frequency, called B2, which is aligned along the x' rotating axis. In the rotating frame the magnetization is parallel to B2, so nothing happens. Why bother? Consider those slight heterogeneities in Bo that led to T2* relaxation. They will cause the spins to dephase, picking up a component in the y' direction. But a component along y' will start to precess around B2. Rather than dephasing, B2 causes the spins to wobble around in the rotating frame, precessing about x', with no net tendency to dephase. You just killed the mechanism leading to T2*! Wow!
Will the spins just precess about B2 forever? No, eventually other mechanisms will cause them to relax toward their equilibrium value. Their time constant will not be T1 or T2 or even T2*, but something else called T1ρ. Typcially, T1ρ is much longer than T2*. To measure T1ρ, apply a 90 degree excitation pulse, then apply a RF spin lock oscillation and record the free induction decay. Fit the decay to an exponential, and the time constant you obtain is T1ρ. (I am not a MRI expert: I am not sure how you can measure a free induction decay when a spin lock field is present. I would think the spin lock field would swamp the FID.)
T1ρ is sometimes measured to learn about the structure of cartilage. It is analogous to T1 relaxation in the laboratory frame, which explains its name. Because B2 is typically much weaker than Bo, T1ρ is sensitive to a different range of correlation times than T1 or T2 (see Fig. 18.12 in IPMB).
When I teach medical physics (PHY 326 here at Oakland University), I go over this derivation in class, but the students still need practice. I have them analyze some related examples as homework. For instance, the oscillating magnetic field can be in the y direction, B1 = B1 cos(ωt) j, or can be shifted in time, B1 = B1 sin(ωt) i. Sometimes I even ask them to analyze what happens when the oscillating magnetic field is in the z direction, B1 = B1 cos(ωt) k, parallel to the static field. This orientation is useless for exciting spins, but is useful as practice.
Yet another way to excite spins is using a circularly polarized magnetic field, B1 = B1 cos(ωt) i – B1 sin(ωt) j. The analysis of this case is similar to the one in IPMB, with one twist: you don’t need to average over time! Below is a new homework problem illustrating this.
Problem 13 1/2. Assume you have a static magnetic field in the z direction and an oscillating, circularly polarized magnetic field in the x-y plane, B =Bo k + B1 cos(ωt) i – B1 sin(ωt) j.
a) Use Eq. 18.12 to derive the equations for the magnetization M in the laboratory frame of reference (ignore relaxation).
b) Use Eq. 18.18 to transform to the rotating coordinate system and derive equations for M'.
c) Interpret these results physically.I get the same equations as derived in IPMB (Eq. 18.25) except for a factor of one half; the angular frequency in the rotating frame is ω1 = γ B1. Not having to average over time makes the result easier to visualize. You don’t get a complex motion that—on average—rotates the magnetization. Instead, you get a plain old rotation. You can understand this behavior qualitatively without any math by realizing that in the rotating coordinate system the RF circularly polarized magnetic field is stationary, pointing in the x’ direction. The spins simply precess around the seemingly static B1'= B1 i', just like the spins precess around the static Bo = Bo k in the laboratory frame.
Now let’s assume that an RF excitation pulse rotates the magnetization so it aligns with the x' rotating axis. Once the pulse ends, what happens? Well, nothing happens unless we account for relaxation. Without relaxation the magnetization precesses around the static field, which means it just sits there stationary in the rotating frame. But we know that relaxation occurs. Consider the mechanism of dephasing, which underlies the T2* relaxation time constant. Slight heterogeneities in Bo mean that different spins precess at different Larmor frequencies, causing the spins to lose phase coherence, decreasing the net magnetization.
Next, consider the case of spin lock. Imagine an RF pulse rotates the magnetization so it is parallel to the x' rotating axis. Then, when the excitation pulse is over, immediately apply a circularly polarized RF pulse at the Larmor frequency, called B2, which is aligned along the x' rotating axis. In the rotating frame the magnetization is parallel to B2, so nothing happens. Why bother? Consider those slight heterogeneities in Bo that led to T2* relaxation. They will cause the spins to dephase, picking up a component in the y' direction. But a component along y' will start to precess around B2. Rather than dephasing, B2 causes the spins to wobble around in the rotating frame, precessing about x', with no net tendency to dephase. You just killed the mechanism leading to T2*! Wow!
Will the spins just precess about B2 forever? No, eventually other mechanisms will cause them to relax toward their equilibrium value. Their time constant will not be T1 or T2 or even T2*, but something else called T1ρ. Typcially, T1ρ is much longer than T2*. To measure T1ρ, apply a 90 degree excitation pulse, then apply a RF spin lock oscillation and record the free induction decay. Fit the decay to an exponential, and the time constant you obtain is T1ρ. (I am not a MRI expert: I am not sure how you can measure a free induction decay when a spin lock field is present. I would think the spin lock field would swamp the FID.)
T1ρ is sometimes measured to learn about the structure of cartilage. It is analogous to T1 relaxation in the laboratory frame, which explains its name. Because B2 is typically much weaker than Bo, T1ρ is sensitive to a different range of correlation times than T1 or T2 (see Fig. 18.12 in IPMB).
Friday, June 5, 2015
Robert Plonsey (1924-2015)
Bioelectricity: A Quantitative Approach, by Plonsey and Barr. |
Plonsey had an enormous impact on my research when I was in graduate school. For example, in 1968 John Clark and Plonsey calculated the intracellular and extracellular potentials produced by a propagating action potential along a nerve axon (“The Extracellular Potential Field of a Single Active Nerve Fiber in a Volume Conductor,” Biophysical Journal, Volume 8, Pages 842−864). Russ and I outline this calculation--which uses Bessel functions and Fourier transforms--in IPMB’s Homework Problem 30 of Chapter 6. In one of my first papers, Jim Woosley, my PhD advisor John Wikswo, and I extended Clark and Plonsey’s calculation to predict the axon’s magnetic field (Woosley, Roth, and Wikswo, 1985, “The Magnetic Field of a Single Axon: A Volume Conductor Model,” Mathematical Bioscience, Volume 76, Pages 1−36). I have described Clark and Plonsey’s groundbreaking work before in this blog.
I associate Plonsey most closely with the development of the bidomain model of cardiac tissue. The 1980s was an exciting time to be doing cardiac electrophysiology, and Duke University, where Plonsey worked, was the hub of this activity. Wikswo, Nestor Sepulveda, and I, all at Vanderbilt University, had to run fast to compete with the Duke juggernaut that included Plonsey, Barr, Ray Ideker, Theo Pilkington, and Madison Spach, as well as a triumvirate of then up-and-coming researchers from my generation: Natalia Trayanova, Wanda Krassowska, and Craig Henriquez. To get a glimpse of these times (to me, the “good old days”), read Henriquez’s “A Brief History of Tissue Models for Cardiac Electrophysiology” (IEEE Transaction on Biomedical Engineering, Volume 61, Pages 1457−1465) published last year.
My first work on the bidomain model was to extend Clark and Plonsey’s calculation of the potential along a nerve axon to an analogous calculation along a cylindrical strand of cardiac tissue, such as a papillary muscle (Roth and Wikswo, 1986, “A Bidomain Model for Extracellular Potential and Magnetic Field of Cardiac Tissue,” IEEE Transaction on Biomedical Engineering, Volume 33, Pages 467−469). I remember what an honor it was for me when Plonsey and Barr cited our paper (and mentioned John and me by name!) in their 1987 article “Interstitial Potentials and Their Change with Depth into Cardiac Tissue” (Biophysical Journal, Volume 51, Pages 547−555). That was heady stuff for a nobody graduate student who could count his citations on his ten fingers.
One day Wikswo returned from a conference and told us about a talk he heard, by either Plonsey or Barr (I don’t recall which), describing the action current distribution produced by a outwardly propagating wave front in a sheet of cardiac tissue (Plonsey and Barr, 1984, “Current Flow Patterns in Two-Dimensional Anisotropic Bisyncytia with Normal and Extreme Conductivities,” Biophysical Journal, Volume 45, Pages 557−571). Wikswo realized immediately that their calculations implied the wave front would have a distinctive magnetic signature, which he and Nestor Sepulveda reported in 1987 (“Electric and Magnetic Fields From Two-Dimensional Anisotropic Bisyncytia,” Biophysical Journal, Volume 51, Pages 557−568).
In another paper, Barr and Plonsey derived a numerical method to solve the bidomain equations including the nonlinear ion channel kinetics (Barr and Plonsey, 1984, “Propagation of Excitation in Idealized Anisotropic Two-Dimensional Tissue,” Biophysical Journal, Volume 45, Pages 1191−1202). This paper was the inspiration for my own numerical algorithm (Roth, 1991, “Action Potential Propagation in a Thick Strand of Cardiac Muscle,” Circulation Research, Volume 68, Pages 162−173). In my paper, I cited several of Plonsey’s articles, including one by Plonsey, Henriquez, and Trayanova about an “Extracellular (Volume Conductor) Effect on Adjoining Cardiac Muscle Electrophysiology” (1988, Medical and Biological Engineering and Computing, Volume 26, Pages 126−129), which shared the conclusion I reached that an adjacent bath can dramatically affect action potential propagation in cardiac tissue. Indeed, Henriquez (Plonsey’s graduate student) and Plonsey were following a similar line of research, resulting in two papers partially anticipating mine (Henriquez and Plonsey, 1990, “Simulation of Propagation Along a Cylindrical Bundle of Cardiac Tissue—I: Mathematical Formulation,” IEEE Transactions on Biomedical Engineering, Volume 37, Pages 850−860; and Henriquez and Plonsey, 1990, “Simulation of Propagation Along a Cylindrical Bundle of Cardiac Tissue—II: Results of Simulation,” IEEE Transactions on Biomedical Engineering, Volume 37, Pages 861−875.)
In parallel with this research, Ideker was analyzing how defibrillation shocks affected cardiac tissue, and in 1986 Plonsey and Barr published two papers presenting their saw tooth model (“Effect of Microscopic and Macroscopic Discontinuities on the Response of Cardiac Tissue to Defibrillating (Stimulating) Currents,” Medical and Biological Engineering and Computing, Volume 24, Pages 130−136; “Inclusion of Junction Elements in a Linear Cardiac Model Through Secondary Sources: Application to Defibrillation,” Volume 24, Pages 127−144). (It’s interesting how many of Plonsey’s papers were published as pairs.) I suspect that if in 1989 Sepulveda, Wikswo and I had not published our article about unipolar stimulation of cardiac tissue (“Current Injection into a Two-Dimensional Anisotropic Bidomain,” Biophysical Journal, Volume 55, Pages 987−999), one of the Duke researchers—perhaps Plonsey himself—would have soon performed the calculation. (To learn more about the Sepulveda et al paper, read my May 2009 blog entry.)
In January 1991 I visited Duke and gave a talk in the Emerging Cardiovascular Technologies Seminar Series, where I had the good fortune to meet with Plonsey. Somewhere I have a videotape of that talk; I suppose I should get it converted to a digital format. When I was working at the National Institutes of Health in the mid 1990s, Plonsey was a member of an external committee that assessed my work, as a sort of tenure review. I will always be grateful for the positive feedback I received, although it was to no avail because budget cuts and a hiring freeze led to my leaving NIH in 1995. Plonsey retired from Duke in 1996, and our paths didn’t cross again. He was a gracious gentleman who I will always have enormous respect for. Indeed, the first seven years of my professional life were spent traveling down a path parallel to and often intersecting his; to put it more aptly, I was dashing down a trail he had blazed.
Robert Plonsey was a World War Two veteran (we are losing them too fast these days), and a leader in establishing biomedical engineering as an academic discipline. You can read his obituary here and here.
I will miss him.
Friday, May 29, 2015
Taylor's Series
In Appendix D of the 5th edition of Intermediate Physics for Medicine and Biology, Russ Hobbie and I review Taylor’s Series. Our Figures D.3 and D.4 show better and better approximations to the exponential function, ex, found by using more and more terms of its Taylor’s series. As we add terms, the approximation improves for small |x| and diverges more slowly for large |x|. Taking additional terms from the Taylor’s series approximates the exponential by higher and higher order polynomials. This is all interesting and useful, but the exponential looks similar to a polynomial, at least for positive x, so it is not too surprising that polynomials do a decent job approximating the exponential.
A more challenging function to fit with a Taylor’s Series would look nothing like a polynomial, which always grows to plus or minus infinity at large |x|. I wonder how the Taylor’s Series does approximating a bounded function; perhaps a function that oscillates back and forth a lot? The natural choice is the sine function.
The Taylor’s Series of sin(x) is
The figure below shows the sine function and its various polynomial approximations.
The red curve is the sine function itself. The simplest approximation is simply sin(x) = x, which gives the yellow straight line. It looks good for |x| less than one, but quickly diverges from sine at large |x|. The green curve is sin(x) = x – x3/6. It rises to a maximum and then falls, much like sin(x), but heads off to plus or minus infinity relatively quickly. The cyan curve is sin(x) = x – x3/6 + x5/120. It captures the first peak of the oscillation well, but then fails. The royal blue curve is sin(x) = x – x3/6 + x5/120 – x7/5040. It is an excellent approximation of sin(x) out to x = π. The violet curve is sin(x) = x – x3/6 + x5/120 – x7/5040 + x9/362880. It begins to capture the second oscillation, but then diverges. You can see the Taylor’s Series is working hard to represent the sine function, but it is not easy.
Appendix D in IPMB gives a table of values of the exponential and its different Taylor’s Series approximations. Below I create a similar table for the sine. Because the sine and all its series approximations are odd functions, I only consider positive values of x.
One final thought. Russ and I title Appendix D as “Taylor’s Series” with an apostrophe s. Should we write “Taylor Series” instead, without the apostrophe s? Wikipedia just calls it the “Taylor Series.” I’ve seen it both ways, and I don’t know which is correct. Any opinions?
A more challenging function to fit with a Taylor’s Series would look nothing like a polynomial, which always grows to plus or minus infinity at large |x|. I wonder how the Taylor’s Series does approximating a bounded function; perhaps a function that oscillates back and forth a lot? The natural choice is the sine function.
The Taylor’s Series of sin(x) is
sin(x) = x – x3/6 + x5/120 – x7/5040 + x9/362880 - …
The figure below shows the sine function and its various polynomial approximations.
The sine function and its various polynomial approximations, from: http://www.peterstone.name/Maplepgs/images/Maclaurin_sine.gif |
Appendix D in IPMB gives a table of values of the exponential and its different Taylor’s Series approximations. Below I create a similar table for the sine. Because the sine and all its series approximations are odd functions, I only consider positive values of x.
A table of values for sin(x) and its various polynomial approximations. |
One final thought. Russ and I title Appendix D as “Taylor’s Series” with an apostrophe s. Should we write “Taylor Series” instead, without the apostrophe s? Wikipedia just calls it the “Taylor Series.” I’ve seen it both ways, and I don’t know which is correct. Any opinions?
Friday, May 22, 2015
Progress Toward a Deployable SQUID-Based Ultra-Low Field MRI System for Anatomical Imaging
When surfing the web, I like to visit medicalphysicsweb.org. This site, maintained by the Institute of Physics, always publishes interesting and up-to-date information about physics applied to medicine. Readers of the 5th Edition of Intermediate Physics for Medicine and Biology should visit it regularly.
A recent article discusses a paper by Michelle Espy and her colleagues about “Progress Toward a Deployable SQUID-Based Ultra-Low Field MRI System for Anatomical Imaging” (IEEE Transactions on Applied Superconductivity, Volume 25, Article Number 1601705, June 2015). The abstract is given below.
A magnetic field of 1500 mT is usually produced by a coil that must be kept at low temperatures to maintain the wire as a superconductor. A 100 mT field does not require superconductivity, but the needed current generates enough heat that the 510-turn copper coil needs to be cooled by liquid nitrogen, and even still the current in the coil must be turned off half the time (50% duty cycle) to avoid overheating.
Once the polarization field turns off, the spins precess with the Larmor frequency for a 0.2 mT magnetic field. The gyromagnetic ratio of protons is 42.6 kHz/mT, implying a Larmor frequency of 8.5 kHz, compared with 64,000 kHz for a clinical machine. So, the Larmor frequencies differ by a factor of 7500.
The magnetic resonance signal recorded in a clinical system is large compared to an ultra-low device because the magnetization is larger by a factor of 15 and the Larmor frequency is larger by a factor of 7500, implying a signal over a hundred thousand times larger. Espy et al. get around this problem by measuring the signal with a Superconducting Quantum Interference Device (SQUID) magnetometer, like those used in magnetoencephalography (see Section 8.9 in IPMB).
Preliminary experiments were performed in a heavy and expensive magnetically shielded room (again, like those used when measuring the MEG). However, second-order gradiometer pickup coils reduce the noise sufficiently that the shielded room is unnecessary.
To perform imaging, Espy et al. use magnetic field gradients of about 0.00025 mT/mm, compared with 0.01 mT/mm gradients typical for clinical MRI. For two objects 1 mm apart, a clinical imaging system would therefore produce a fractional frequency shift of 0.01/1500 = 0.0000067 or 6.7 ppm, whereas a low-field device has a fractional shift of 0.00025/0.2 = 0.00125 or 1250 ppm. Therefore, the clinical magnetic field needs to be extremely homogeneous (on the order of parts per million) to avoid artifacts, whereas a low-field device can function with heterogeneities hundreds of times larger.
The relaxation time constants for gray matter in the brain are reported by Espy et al. as about T1 = 600 ms and T2 = 80 ms. In clinical devices, the value of T1 is about half that, and T2 is about the same. Based on Figure 18.12 and Equation 18.35 in IPMB, I’m not surprised that T2 is largely independent of the magnetic field strength. However, in strong fields T1 increases as the square of the magnetic field (or the square of the Larmor frequency), so I was initially expecting a much smaller value of T1 for the low-field device. But once the Larmor frequency drops to values less than the typical correlation time of the spins, T1 becomes independent of the magnetic field strength (Equation 18.34 in IPMB). I assume that is what is happening here, and explains why T1 drops by only a factor of two when the magnetic field is reduced by a factor of 7500.
I find the differences between radio-frequency excitation pulses to be interesting. In clinical imaging, if the excitation pulse has a duration of about 1 ms and the Larmor frequency is 64,000 kHz, there are 64,000 oscillations of the radio-frequency magnetic field in a single π/2 pulse. Espy et al. used a 4 ms duration excitation pulse and a Larmor frequency of 8.5 kHz, implying just 34 oscillations per pulse. I have always worried that illustrations such as Figure 18.23 in IPMB mislead because they show the Larmor frequency as being not too different from the excitation pulse duration. For low-field MRI, however, this picture is realistic.
Does low-field MRI have advantages? You don’t need the heavy, expensive superconducting coil to generate a large static field, but you do need SQUID magnetometers to record the small signal, so you don’t avoid the need for cryogenics. The medicalphysicsweb article weighs the pros and cons. For instance, the power requirements for a low-field device are relatively small, and it is more portable, but the imaging times are long. The safety hazards caused by metal are much less in a low-field system, but the impact of stray magnetic fields is greater. I’m skeptical about the ultimate usefulness of ultra low-field MRI, but it’ll be fun to watch if Espy and her team can prove me wrong.
A recent article discusses a paper by Michelle Espy and her colleagues about “Progress Toward a Deployable SQUID-Based Ultra-Low Field MRI System for Anatomical Imaging” (IEEE Transactions on Applied Superconductivity, Volume 25, Article Number 1601705, June 2015). The abstract is given below.
Magnetic resonance imaging (MRI) is the best method for non-invasive imaging of soft tissue anatomy, saving countless lives each year. But conventional MRI relies on very high fixed strength magnetic fields, ≥ 1.5 T, with parts-per-million homogeneity, requiring large and expensive magnets. This is because in conventional Faraday-coil based systems the signal scales approximately with the square of the magnetic field. Recent demonstrations have shown that MRI can be performed at much lower magnetic fields (∼100 μT, the ULF regime). Through the use of pulsed prepolarization at magnetic fields from ∼10–100 mT and SQUID detection during readout (proton Larmor frequencies on the order of a few kHz), some of the signal loss can be mitigated. Our group and others have shown promising applications of ULF MRI of human anatomy including the brain, enhanced contrast between tissues, and imaging in the presence of (and even through) metal. Although much of the required core technology has been demonstrated, ULF MRI systems still suffer from long imaging times, relatively poor quality images, and remain confined to the R and D laboratory due to the strict requirements for a low noise environment isolated from almost all ambient electromagnetic fields. Our goal in the work presented here is to move ULF MRI from a proof-of-concept in our laboratory to a functional prototype that will exploit the inherent advantages of the approach, and enable increased accessibility. Here we present results from a seven-channel SQUID-based system that achieves pre-polarization field of 100 mT over a 200 cm3 volume, is powered with all magnetic field generation from standard MRI amplifier technology, and uses off the shelf data acquisition. As our ultimate aim is unshielded operation, we also demonstrated a seven-channel system that performs ULF MRI outside of heavy magnetically-shielded enclosure. In this paper we present preliminary images and compare them to a model, and characterize the present and expected performance of this system.Let’s compare a standard 1.5-Tesla clinical MRI system with Espy et al.’s ultra-low field device. To compare quantities using the same units, I will always express the magnetic field strength in mT; a typical clinical MRI machine has a field of 1500 mT. In Section 18.3 of IPMB, Russ Hobbie and I show that the magnetization depends linearly on the magnetic field strength (Equation 18.9). The static magnetic field of Espy et al.’s machine is 0.2 mT, but for 4000 ms before spin excitation a polarization magnetic field of 100 mT is turned on. Thus, there is a difference of a factor of 15 in the magnetization, with the ultra-low device having less and the clinical machine more. Once the polarization field is turned off, the magnetic field in the ultra-low device reduces to 0.2 mT. This is only four times the earth’s magnetic field, about 0.05 mT. Espy et al. use Hemlholtz coils to cancel the earth’s field.
A magnetic field of 1500 mT is usually produced by a coil that must be kept at low temperatures to maintain the wire as a superconductor. A 100 mT field does not require superconductivity, but the needed current generates enough heat that the 510-turn copper coil needs to be cooled by liquid nitrogen, and even still the current in the coil must be turned off half the time (50% duty cycle) to avoid overheating.
Once the polarization field turns off, the spins precess with the Larmor frequency for a 0.2 mT magnetic field. The gyromagnetic ratio of protons is 42.6 kHz/mT, implying a Larmor frequency of 8.5 kHz, compared with 64,000 kHz for a clinical machine. So, the Larmor frequencies differ by a factor of 7500.
The magnetic resonance signal recorded in a clinical system is large compared to an ultra-low device because the magnetization is larger by a factor of 15 and the Larmor frequency is larger by a factor of 7500, implying a signal over a hundred thousand times larger. Espy et al. get around this problem by measuring the signal with a Superconducting Quantum Interference Device (SQUID) magnetometer, like those used in magnetoencephalography (see Section 8.9 in IPMB).
Preliminary experiments were performed in a heavy and expensive magnetically shielded room (again, like those used when measuring the MEG). However, second-order gradiometer pickup coils reduce the noise sufficiently that the shielded room is unnecessary.
To perform imaging, Espy et al. use magnetic field gradients of about 0.00025 mT/mm, compared with 0.01 mT/mm gradients typical for clinical MRI. For two objects 1 mm apart, a clinical imaging system would therefore produce a fractional frequency shift of 0.01/1500 = 0.0000067 or 6.7 ppm, whereas a low-field device has a fractional shift of 0.00025/0.2 = 0.00125 or 1250 ppm. Therefore, the clinical magnetic field needs to be extremely homogeneous (on the order of parts per million) to avoid artifacts, whereas a low-field device can function with heterogeneities hundreds of times larger.
The relaxation time constants for gray matter in the brain are reported by Espy et al. as about T1 = 600 ms and T2 = 80 ms. In clinical devices, the value of T1 is about half that, and T2 is about the same. Based on Figure 18.12 and Equation 18.35 in IPMB, I’m not surprised that T2 is largely independent of the magnetic field strength. However, in strong fields T1 increases as the square of the magnetic field (or the square of the Larmor frequency), so I was initially expecting a much smaller value of T1 for the low-field device. But once the Larmor frequency drops to values less than the typical correlation time of the spins, T1 becomes independent of the magnetic field strength (Equation 18.34 in IPMB). I assume that is what is happening here, and explains why T1 drops by only a factor of two when the magnetic field is reduced by a factor of 7500.
I find the differences between radio-frequency excitation pulses to be interesting. In clinical imaging, if the excitation pulse has a duration of about 1 ms and the Larmor frequency is 64,000 kHz, there are 64,000 oscillations of the radio-frequency magnetic field in a single π/2 pulse. Espy et al. used a 4 ms duration excitation pulse and a Larmor frequency of 8.5 kHz, implying just 34 oscillations per pulse. I have always worried that illustrations such as Figure 18.23 in IPMB mislead because they show the Larmor frequency as being not too different from the excitation pulse duration. For low-field MRI, however, this picture is realistic.
Does low-field MRI have advantages? You don’t need the heavy, expensive superconducting coil to generate a large static field, but you do need SQUID magnetometers to record the small signal, so you don’t avoid the need for cryogenics. The medicalphysicsweb article weighs the pros and cons. For instance, the power requirements for a low-field device are relatively small, and it is more portable, but the imaging times are long. The safety hazards caused by metal are much less in a low-field system, but the impact of stray magnetic fields is greater. I’m skeptical about the ultimate usefulness of ultra low-field MRI, but it’ll be fun to watch if Espy and her team can prove me wrong.
Friday, May 15, 2015
What My Dogs Forced Me To Learn About Thermal Energy Transfer
I’m a dog lover, so I have to enjoy an American Journal of Physics paper that begins “For many years, I have competed and judged in American Kennel Club obedience trials.” The title of the paper is also delightful: “What my Dogs Forced Me to Learn About Thermal Energy Transfer” (Craig Bohren, American Journal of Physics, Volume 83, Pages 443−446, 2015). Bohren’s hypothesis is that an animal perceives hotness and coldness not directly from an object’s temperature, as one might naively expect, but from the flux density of thermal energy. I could follow his analysis of this idea, but I prefer to use the 5th edition of Intermediate Physics for Medicine and Biology, because Russ Hobbie and I have already worked out almost all the results we need.
Chapter 4 of IPMB analyzes diffusion. We consider the concentration, C, of particles as they diffuse in one dimension. Initially (t = 0), there exists a concentration difference C0 between the left and right sides of a boundary at x = 0. We solve the diffusion equation in this case, and find the concentration in terms of an error function
where D is the diffusion constant. A plot of C(x,t) is shown in Fig. 4.22 (we assume C = 0 on the far right, but you could add a constant to the solution without changing the physics, so all that really matters is the concentration difference).
In Homework Problem 19, Russ and I show that the analysis of particle diffusion is equivalent to an analysis of heat conduction, with the thermal diffusivity D given by the thermal conductivity, κ, divided by the specific heat capacity, c, and the density, ρ
So, by analogy, if you start (t = 0) with a uniform temperature on the left and on the right sides of a boundary at x = 0, with an initial temperature difference ΔT between sides, the temperature distribution T(x,t) is (to within a additive constant temperature) the same as the concentration distribution calculated earlier.
The temperature of the interface is always ΔT/2. If a dog responded to simply the temperature at x = 0 (where its thermoreceptors are presumably located), it would react in a way strictly proportional to the temperature difference ΔT. But Bohren’s hypothesis is that thermoreceptors respond to the energy flux density, κ dT/dx.
Now let us look again at Fig. 4.22. The slope of the curve at x = 0 is the key quantity. So, we must differentiate our expression for T(x,t). We get
By the chain rule, this becomes (with u = x/√4Dt)
The derivative of the error function is given in IPMB on page 179
At the interface (u = 0), this becomes 2/√π. Therefore
Bohren comes to the same result, but by a slightly different argument.
The energy flux density depends on time, with an infinite response initially (we assume an abrupt difference of temperature on the two sides of the boundary x = 0) that falls to zero as the time becomes large. The flux density depends on the material parameters by the quantity κ/√D , which is equivalent to √cρκ and is often called the thermal inertia.
Bohren goes on to analyze the case when the two sides have different properties (for example, the left might be a piece of aluminum, and the right a dog’s tongue), and shows that you get a similar result except the effective thermal inertia is a combination of the thermal inertia on the left and right. He does not solve the entire bioheat equation (Sec. 14.11 in IPMB), including the effect of blood flow. I would guess that blood flow would have little effect initially, but it would play a greater and greater role as time goes by.
Perhaps I will try Bohren’s experiment: I’ll give Auggie (my daughter Kathy’s lovable foxhound) a cylinder of aluminum and a cylinder of stainless steel, and see if he can distinguish between the two. My prediction is that, rather than either metal, he prefers rawhide.
Chapter 4 of IPMB analyzes diffusion. We consider the concentration, C, of particles as they diffuse in one dimension. Initially (t = 0), there exists a concentration difference C0 between the left and right sides of a boundary at x = 0. We solve the diffusion equation in this case, and find the concentration in terms of an error function
C(x,t) = C0/2 [ 1 – erf(x/√4Dt) ] , Eq. 4.75
where D is the diffusion constant. A plot of C(x,t) is shown in Fig. 4.22 (we assume C = 0 on the far right, but you could add a constant to the solution without changing the physics, so all that really matters is the concentration difference).
Fig. 4.22 The spread of an initially sharp boundary due to diffusion. |
D = κ/cρ .
So, by analogy, if you start (t = 0) with a uniform temperature on the left and on the right sides of a boundary at x = 0, with an initial temperature difference ΔT between sides, the temperature distribution T(x,t) is (to within a additive constant temperature) the same as the concentration distribution calculated earlier.
T(x,t) = ΔT /2 [ 1 – erf(x/√4Dt) ] .
The temperature of the interface is always ΔT/2. If a dog responded to simply the temperature at x = 0 (where its thermoreceptors are presumably located), it would react in a way strictly proportional to the temperature difference ΔT. But Bohren’s hypothesis is that thermoreceptors respond to the energy flux density, κ dT/dx.
Now let us look again at Fig. 4.22. The slope of the curve at x = 0 is the key quantity. So, we must differentiate our expression for T(x,t). We get
κ dT/dx = - κ ΔT/2 d/dx [ erf(x/√4Dt) ] .
By the chain rule, this becomes (with u = x/√4Dt)
κ dT/dx = - κ ΔT / (2 √4Dt ) d(erf(u))/du .
The derivative of the error function is given in IPMB on page 179
d/du (erf(u)) = 2/√π e-u2 .
At the interface (u = 0), this becomes 2/√π. Therefore
κ dT/dx = - κ ΔT /√4πDt .
Bohren comes to the same result, but by a slightly different argument.
The energy flux density depends on time, with an infinite response initially (we assume an abrupt difference of temperature on the two sides of the boundary x = 0) that falls to zero as the time becomes large. The flux density depends on the material parameters by the quantity κ/√D , which is equivalent to √cρκ and is often called the thermal inertia.
Bohren goes on to analyze the case when the two sides have different properties (for example, the left might be a piece of aluminum, and the right a dog’s tongue), and shows that you get a similar result except the effective thermal inertia is a combination of the thermal inertia on the left and right. He does not solve the entire bioheat equation (Sec. 14.11 in IPMB), including the effect of blood flow. I would guess that blood flow would have little effect initially, but it would play a greater and greater role as time goes by.
Perhaps I will try Bohren’s experiment: I’ll give Auggie (my daughter Kathy’s lovable foxhound) a cylinder of aluminum and a cylinder of stainless steel, and see if he can distinguish between the two. My prediction is that, rather than either metal, he prefers rawhide.
Friday, May 8, 2015
The blog is dead. Long live the blog!
Intermediate Physics for Medicine and Biology. |
Next week will be the first entry to the blog for the FIFTH edition of Intermediate Physics for Medicine and Biology! You can now purchase the 5th edition at the Springer website. Amazon does not have a page for the book yet, but it should be coming soon.
What’s new in the 5th edition? The preface states
The Fifth Edition does not add any new chapters, but almost every page has been improved and updated. Again, we fought the temptation to expand the book and deleted material when possible. Some of the deleted material is available at the book’s website: [https://sites.google.com/view/hobbieroth]. The Fifth Edition has 12% more end-of-chapter problems than the Fourth Edition; most highlight biological applications of the physical principles. Many of the problems extend the material in the text. A solutions manual is available to those teaching the course. Instructors can use it as a reference or provide selected solutions to their students. The solutions manual makes it much easier for an instructor to guide an independent-study student. Information about the solutions manual is available at the book’s website.The 5th edition is only 13 pages longer than the 4th. By deleting or condensing obsolete or less important topics, we made room for some new sections, including
- 1.2 Models (about toy models and their different roles in biology and physics)
- 1.15 Diving (SCUBA diving and the bends)
- 2.6 The Chemostat
- 8.1.2 The Cyclotron
- 8.8.4 Magnetic nanoparticles
- 9.10.5 Microwaves, Mobile Phones, and Wi-Fi
- 10.7 Proportional, Derivative, and Integral Control
- 13.1.3 Shear waves
- 13.7.4 Elastography (using ultrasound imaging)
- 13.7.5 Safety (of ultrasound imaging)
- 14.2 Electron Waves and Particles: The Electron Microscope
- 14.9.2 Photodynamic Therapy
- 14.15 Color Vision
- 18.14 Hyperpolarized MRI of the Lung
Enjoy!
Friday, May 1, 2015
Churchill’s moral
The Second World War, by Winston Churchill. |
One unique feature of Churchill’s history is that he gave it a moral:
Moral of the Work
In War: Resolution
In Defeat: Defiance
In Victory: Magnanimity
In Peace: Goodwill
All books should have a moral, which sums up its key message in just a handful of carefully chosen words, and highlights the crucial lessons readers should learn. A moral is not an abstract, meant to summarize the book. Rather than explaining what the book is about, a moral tells why you should bother reading the book at all.
What would be the moral of the 4th edition of Intermediate Physics for Medicine and Biology? I cannot capture the essence of IPMB as well as Churchill did his history, but I must try. The moral of IPMB should express how physics explains and constrains biology and medicine, how you cannot truly understand biology until you can describe it in the language of mathematics, how so much of what is learned in introductory physics has direct applications to modern medicine, how toy models provide a way to reduce complex biological processes to their fundamental mechanisms, how the goal of expressing phenomena in mathematics is not merely to calculate numbers but to tell a physical story, and how solving homework problems is the most important way (more important that reading the book!) to learn crucial modeling skills. So, with apologies to Sir Winston, I present the moral of Intermediate Physics for Medicine and Biology:
Moral of the Work
In Physics: Physiology
In Math: Medicine
In Models: Comprehension
In Equations: Insight
Friday, April 24, 2015
Figure 13.5
In Chapter 13 of the 4th edition of Intermediate Physics for Medicine and Biology, Russ Hobbie and I discuss imaging using ultrasound. One of the key concepts in this chapter is the reflection of an ultrasonic wave at the boundary between tissues having different acoustic impedances. The acoustic impedance is equal to the square root of ρ/κ, where ρ is the density and κ is the compressibility. An ultrasonic image is formed by recording echoes of an ultrasonic wave and using the timing of those echoes to determine the distance from tissue boundaries.
Figure 13.5 shows schematically how part of a pressure wave approaching a surface (the incident wave) passes through the surface (the transmitted wave) and part travels back toward the wave’s source (the reflected wave, or echo). When you look closely, however, there is something odd about this figure: the transmitted wave has a larger amplitude than the incident wave. How can this be? Doesn’t this violate some conservation law? If we consider particles rather than waves, we would expect that if 100 particles were incident on a surface, perhaps 75 of them would be transmitted and 25 reflected. Figure 13.5 seems to imply that 100 incident particles result in 133 transmitted and 33 reflected! How?
The figure is not wrong; the problem is with our intuition. Pressure is not a conserved quantity. There is no reason to expect the sum of the pressures of the transmitted and reflected waves to equal the pressure of the incident wave. The amplitudes are consistent with equations 13.26 and 13.27 in IPMB relating the three waves. Yet there is a conserved quantity, one we all know: energy.
The intensity of a wave is the energy per unit area per unit time. The intensity I, pressure p, and acoustic impedance Z are related by equation 13.29: I = p2/2Z. The transmitted wave in Fig. 13.5 has a pressure amplitude that is 1.33 times the amplitude of the incident wave, but it is moving through a tissue that has twice the acoustic impedance (the caption says that for this figure, Z2 = 2 Z1). For simplicity, take the acoustic impedance on the left (the incident side of the boundary, region 1) to be Z1 = 0.5 and the amplitude of the incident wave to be pi = 1 (let’s not worry about units for now, because our goal is to compare the relative intensities of the three waves). In this case, the intensity of the incident wave is equal to one. If the transmitted pressure is 1.33 and the acoustic impedance on the right (region 2) is Z2 = 1 (twice Z1), then the transmitted intensity is (1.33)2/2 = 0.89. The reflected wave has amplitude 0.33, and is propagating through the tissue on the left, so its intensity is (0.33)2/1 = 0.11. The sum of the intensities of the transmitted and reflected waves, 0.89 + 0.11, is equal to the intensity of the incident wave. Energy is conserved! The figure is correct after all.
Here is another way to think about intensity: it’s one half of the product of the pressure times the tissue speed. When I say “tissue speed” I don’t mean the propagation speed of the wave, but the speed of the tissue itself as it oscillates back and forth. The acoustic impedance relates the pressure and tissue speed. The large pressure of the transmitted wave is associated with a small tissue speed. The transmitted wave in Fig. 13.5 looks “big” only because we plot the pressure. Had we plotted tissue speed instead, we would not be wondering why the transmitted wave has such a large amplitude. We would, however, be scratching our head about a funny phase shift in the reflected wave, which the version of the figure showing the pressure hides.
So, Fig. 13.5 is correct. Does that mean it looks exactly the same in the 5th edition of IPMB (due out this summer)? No, we did change the figure; not to correct an error, but to emphasize another point. Figure 13.5, as presently drawn, shows the wavelength of the transmitted wave to be the same as the wavelength of the incident wave. The wavelength does not depend on the acoustic impedance, but it does depend on the wave speed (the propagation speed of the wave itself, usually given the symbol c, which is not the same as the speed of the oscillating tissue). The wave speed is equal to the square root of the reciprocal of the product of the density and compressibility. One can cook up examples where two tissues have the same wave speed but different acoustic impedances. For instance (again, not worrying about units and only comparing relative sizes), if the tissue on the left had twice the compressibility and half the density of the tissue on the right, then the left would have half the acoustic impedance and the same wave speed as the right, just as shown in Fig. 13.5. But tissues usually differ in compressibility by a greater factor than they differ in density. If we assume the two regions have the same density but the right has one-fourth the compressibility, then Z2 = 2 Z1 as before but also c2 = 2 c1, so the wavelength is longer on the right. In the 5th edition, the figure now shows the wavelength longer on the right.
What is the moral to this story? Readers (and authors) need to think carefully about illustrations such as Fig. 13.5. They tell a physical story that is often richer and more complicated than we may initially realize.
Figure 13.5 from Intermediate Physics for Medicine and Biology. |
The figure is not wrong; the problem is with our intuition. Pressure is not a conserved quantity. There is no reason to expect the sum of the pressures of the transmitted and reflected waves to equal the pressure of the incident wave. The amplitudes are consistent with equations 13.26 and 13.27 in IPMB relating the three waves. Yet there is a conserved quantity, one we all know: energy.
The intensity of a wave is the energy per unit area per unit time. The intensity I, pressure p, and acoustic impedance Z are related by equation 13.29: I = p2/2Z. The transmitted wave in Fig. 13.5 has a pressure amplitude that is 1.33 times the amplitude of the incident wave, but it is moving through a tissue that has twice the acoustic impedance (the caption says that for this figure, Z2 = 2 Z1). For simplicity, take the acoustic impedance on the left (the incident side of the boundary, region 1) to be Z1 = 0.5 and the amplitude of the incident wave to be pi = 1 (let’s not worry about units for now, because our goal is to compare the relative intensities of the three waves). In this case, the intensity of the incident wave is equal to one. If the transmitted pressure is 1.33 and the acoustic impedance on the right (region 2) is Z2 = 1 (twice Z1), then the transmitted intensity is (1.33)2/2 = 0.89. The reflected wave has amplitude 0.33, and is propagating through the tissue on the left, so its intensity is (0.33)2/1 = 0.11. The sum of the intensities of the transmitted and reflected waves, 0.89 + 0.11, is equal to the intensity of the incident wave. Energy is conserved! The figure is correct after all.
Here is another way to think about intensity: it’s one half of the product of the pressure times the tissue speed. When I say “tissue speed” I don’t mean the propagation speed of the wave, but the speed of the tissue itself as it oscillates back and forth. The acoustic impedance relates the pressure and tissue speed. The large pressure of the transmitted wave is associated with a small tissue speed. The transmitted wave in Fig. 13.5 looks “big” only because we plot the pressure. Had we plotted tissue speed instead, we would not be wondering why the transmitted wave has such a large amplitude. We would, however, be scratching our head about a funny phase shift in the reflected wave, which the version of the figure showing the pressure hides.
So, Fig. 13.5 is correct. Does that mean it looks exactly the same in the 5th edition of IPMB (due out this summer)? No, we did change the figure; not to correct an error, but to emphasize another point. Figure 13.5, as presently drawn, shows the wavelength of the transmitted wave to be the same as the wavelength of the incident wave. The wavelength does not depend on the acoustic impedance, but it does depend on the wave speed (the propagation speed of the wave itself, usually given the symbol c, which is not the same as the speed of the oscillating tissue). The wave speed is equal to the square root of the reciprocal of the product of the density and compressibility. One can cook up examples where two tissues have the same wave speed but different acoustic impedances. For instance (again, not worrying about units and only comparing relative sizes), if the tissue on the left had twice the compressibility and half the density of the tissue on the right, then the left would have half the acoustic impedance and the same wave speed as the right, just as shown in Fig. 13.5. But tissues usually differ in compressibility by a greater factor than they differ in density. If we assume the two regions have the same density but the right has one-fourth the compressibility, then Z2 = 2 Z1 as before but also c2 = 2 c1, so the wavelength is longer on the right. In the 5th edition, the figure now shows the wavelength longer on the right.
What is the moral to this story? Readers (and authors) need to think carefully about illustrations such as Fig. 13.5. They tell a physical story that is often richer and more complicated than we may initially realize.