The next big advance was patch-clamp recording (Neher
and Sakmann 1976). Micropipettes were sealed against
a cell membrane that had been cleaned of connective tissue
by treatment with enzymes. A very-high-resistance seal
resulted [(2–3) × 107 Ω] that allowed one to see the opening
and closing of individual channels. For this work, Erwin Neher and Bert Sakmann received the Nobel Prize in Physiologyor Medicine in 1991.
Fifty years ago, Erwin Neher and Bert Sakmann published a Nature paper on their recording of discrete, step-like currents of a few picoamps passing through individual acetylcholine receptor channels of frog muscle fibers. This observation, the first on native channels, immediately ended the decade-long dispute about the presence of ion channels on cell membranes by convincing even the most reluctant scientists that this was indeed the case. More importantly, however, the ability to record single-channel currents revolutionized the study of ion channels because it enabled scientists to observe their behavior individually in real time. We could observe them change conformation, jumping from the closed state to the open state and back again. This level of detail provided an unprecedented understanding of the gating mechanisms, conductance, and kinetic properties of channels. This retrospective illustrates the scientific context in which all of this occurred as well as its immediate and current impact on the investigation of ion channels.
Below is the graphical abstract
The review is a nice mix of history and science. I recommend it to anyone wanting to learn more about the patch clamping. Here is the section about how Neher and Sakmann met and began their collaboration.
This crucial scientific objective of recording single-channel
currents apparently fraught with insurmountable
problems found a solution when it crossed the paths of two
young German scientists, Erwin Neher and Bert Sakmann.
Erwin Neher had returned to Germany in 1967 after a year
on a Fulbright studentship at the University of Wisconsin,
where he studied spectroscopy of macromolecules, and was
now looking around for some PhD project in biophysics,
possibly related to nerve excitation. This search brought him
to Prof Dieter Lux’s laboratory at the Max-Planck-Institutfür Psychiatrie in Munich to study synaptic mechanisms in
snail motor neurons. To avoid space clamp problems, Lux
recommended that his young postdoc use suction pipettes
to record currents. This suggestion would be recalled a
few years later when trying to record elementary currents
through single-channel.
While at Prof Lux’s laboratory, Neher met Bert Sakmann
who had come to learn the basics of voltage clamping synaptic
currents in snail neurons before moving to University College London to work in Bernard Katz’s biophysics
laboratory on that topic. Sakmann was eager to understand
the fundamental mechanisms of the synapse that Neher
was studying because he believed they were essential to
comprehending the central nervous system’s excitability.
For this reason, they had many lively discussions... It was in that period that Katz, in collaboration with
Ricardo Miledi, suggested that elementary current events
through individual ACh receptor channels caused the noise
observed in the membrane potential recordings when ACh
was applied to the end-plates of frog skeletal muscle (Katz
& Miledi 1972 ).
Neher and Sakmann met again at the Max-Planck-Institutfür Biophysikalische Chemie in Götttingen in 1973.
Neher had joined the Institute to gain expertise in single-channel
recording in artificial lipid bilayers, and Sakmann
had returned from London and was offered by Prof Otto Creutzfeldt to run his independent laboratory. Given their
clear communion of interests, they soon agreed on collaborating
to measure single-channel currents.
I’ll end by quoting Catacuzzeno and Franciolini's concluding paragraph.
The single-channel recording technique, with its many configurations
for different experimental needs, has been invaluable
in many areas of research over the years. The technique
certainly has its limitations, such as low data throughput or
the requirement for highly skilled operators. However, there
is a general consensus that classical single-channel recording
with patch clamp, when performed by expert scientists,
remains the technique capable of providing the highest-quality
data and the most reliable answers to subtle questions
about ion channels. Despite being the oldest single-molecule
technique and having changed little over the last 45 years,
this technique remains a milestone in the study of protein
conformational dynamics. Due to its unparalleled recording
length (with many thousands of openings and closures) and
sub-millisecond time resolution, it is the only technique that
allows one to observe, in real time, when channels open or
close (i.e., switch conformation) while remaining in their
natural environment within the cell membrane.
No comments: